A mature module category for dependable commercial, industrial and ground-mounted applications. Final selection must use the applicable model, approved datasheet, site conditions and engineering review.
Established cell architecture
Flexible project use
Configuration-dependent module formats
Product classification
Technology
Mono PERC
Construction
Monofacial / Bifacial
Verified power range
385-600 Wp
Verified efficiency range
19.64%-21.70%
Cell format
M10 Mono PERC half-cut
Applications
Commercial rooftop, Industrial, Solar EPC
Verified product variants
Electrical characteristics
STC: irradiance 1000 W/m², spectrum AM1.5 and cell temperature 25°C. Except Pmax, other parameters have a tolerance of ±3% as stated in the source sheets.
Monofacial
108 Half Cut Cell Mono PERC Mono-facial Module
SLM-M10-108-XXX
385-415 Wp
Manual review required: The source sheet contains non-sequential voltage values. Values are reproduced exactly and require engineering confirmation before publication.
STC electrical values for SLM-M10-108-XXX
Pmax (Wp)
Voc (V)
Isc (A)
Vmp (V)
Imp (A)
Efficiency (%)
385
36.88
13.28
30.88
12.47
19.72
390
36.92
13.43
30.92
12.61
19.97
395
36.96
13.59
30.96
12.76
20.23
400
37
13.74
31
12.9
20.48
405
37.3
13.81
31.04
13.04
20.75
410
37.5
13.87
31.08
13.19
21
415
37.7
13.95
31.12
13.34
21.25
Mechanical characteristics
Module
SLM-M10-108-XXX
Construction
Monofacial
Cells
108 half-cut cells
Dimensions
1722 x 1134 x 35 mm
Weight
21.5 kg
Front glass
3.2 mm high-transmission, low-iron, ARC tempered glass
Frame
Anodized aluminium alloy (silver/black)
Junction box
IP68 certified, 3 bypass diodes
Cable
Solar cable 4 mm²; lengths vary by series and customization
Connectors
MC4-compatible connectors
Temperature & operating conditions
Power tolerance
0 to +5 W
Temperature coefficient Voc
-0.28%/°C
Temperature coefficient Isc
0.05%/°C
Temperature coefficient Pmax
-0.35%/°C
NOCT
45°C ± 2°C
Operating range
-40°C to 85°C
Maximum system voltage
1500 V DC
Snow / wind load
5400 Pa / 2400 Pa
Hail resistance
Maximum 24 mm with impact speed of 83 km/h
Warranty & compliance
Documented source claims
12 years on materials and workmanship (source cover claim)
30-year linear performance claim on source cover; the plotted chart ends at year 27 and therefore requires manual warranty confirmation.
IEC 61730
IEC 62804 (PID)
IEC 61701 (Salt Mist)
IEC 61853
ISO 9001
ISO 14001
ISO 45001
IS 14286
IS 61730-1 & 2
G2B is described by the supplied sheet as glass-to-backsheet. Certification and warranty marks must be verified against original certificates before being presented as approved company accreditations.
Original documents
Datasheet preview & download
Original client-supplied PDFs are preserved without alteration.